Major Features
Small in volume、light in weight and convenient in carrying
Operation of the product is simple ,low power consumption
Operation menu for the function setting
SpO2 value display
Pulse rate value display, bar graph display
Pulse waveform display
With backlight
A pulse rate sound indication
With measured data overruns limits and low-voltage alarm function, the upper/down alarm range is adjustable
Battery capacity indication
Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage ,and with alarm function
Real-time data can be transmitted to computers(Option)
Connected with an external oximeter probe
Main performance

Display Mode: LCD display
Screen Resolution: 160*96
SpO2 Measuring Range: 0%~100%, (the resolution is 1%).
Accuracy: 70%~100%2% ,Below 70% unspecified.
PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm)
Accuracy2bpm or ±2% (select larger)
Measurement Performance in Weak Filling Condition:
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to Surrounding Light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Power Consumption: less than 80mA
Voltage: DC 3.0V
Power Supply: 1.5V (AA size) alkaline batteries2
Battery Working Hour: Two batteries can work continually for 28 hours(without backlight)
Safety Type: Interior Battery, BF Type

Accessories

Sell in standard:
A user manual
An oximeter probe
Sell in addition:
A data line
A disk (PC software)
Other oximeter probe(Refer to probe application instruction for details and notice renewal)
Physical Identity
Dimension: 109(L)95(W)40(H) mm
Weight: About 215g (with the batteries)
Qualification

Passed CE
Optional color:

Cms60A handheld Pulse oximeter
Technical Parameters

Display Format: LCD;Back light: LED

SPO2:35-99% ; Pulse Ratio:30-250 BPM

Pulse Ratio:30-250 BPM; Spo2 Alarm Range: 0-100%

Pulse Alarm Range: 15-300 BPM

Pulse Wave: LCD Graphic Display

Battery Voltage Low Indication: LCD signals.

Power: CMS60A:Two AA size 1.5V Alkali Battery; CMS60B:3.7V Li-ion Battery

Power Consumption: less than 20 mA.

Resolution: ±1 for SPO2 and ±1 BPM for Pulse Ratio.

Measurement Accuracy: ±2 in stage of 70%-99% SPO2 and meaningless when stage

being smaller than 70%. ±2BPMfor Pulse Ratio.

Measurement Performance in Weak Filling ConditionOxyhemoglobin and pulse
#118alue
can be shown correctly when pulse-filling ratio is 0.4%.

Interference Resistance Capacity against Ambient LightDeviation is smaller than ±
1
% between #118alue of Oxyhemoglobin measured in natural lighting indoor condition and present
lighting sources and
that measured in dark room.

Option: ECG waveform Display, Heart rate, HR Alarm, SD Card for 24 hours storage,

CMS60 Handheld Pulse oximeter on sale

Products Showcase

See more products from this supplier.

Do you want to show products of your own company? Join FREE now!

You may also be interested in: